B-62994EN/02 APPENDIX 1 REQUIRED NC SETTING FOR EACH BASIC OPERATION PACKAGE 1 SCREEN
-415-
40 Operation History Screen
FS16/18/21/NC Board :
Supported NC FS16/160-MB/TB/MMB/TTB, FS16/160-MC/TC/MMC/TTC, FS16i/160i-MA/TA
FS18/180-MB/TB/TTB, FS18/180-MC/TC/TTC, FS18i/180i-MA/TA
FS21/210-MB/TB, FS21i/210i-MA/TA
NC Board-M/T
Option None (Basic)
NC parameter setting or
NC mode relating to this
screen
Parameter 3106#4 = 1
Parameter 3112#5 = 0
Parameter 3110#4 = 0 Do not display soft key "Delete".
= 1 Display soft key "Delete".
FS15:
Supported NC FS15/150-MB/TB/TTB
Option None (Basic)
NC parameter setting or
NC mode relating to this
screen
Parameter 0015#3 = 1
Parameter 0015#4 = 0 Do not display soft key "Delete".
= 1 Display soft key "Delete".
Parameter 0013#5 = 0 Do not display soft key "Signal Select".
= 1 Display soft key "Signal Select".
Power Mate:
Supported NC Power Mate-D/H
Power Mate i-D/H
Option None (Basic)
NC parameter setting or
NC mode relating to this
screen
Parameter 3106#4 = 1
Parameter 3112#5 = 0
41 PMC Screens
([PMC Status], [PMC Alarm], [PMC Counter], [PMC Timer], [PMC Keep relay], [PMC Data] Screen)
PMC FS16/18/21/NC Board : all types of PMC-RB/RC
FS15 : PMC-NB/NB2
Power Mate
Option None (Basic)
NC parameter setting or
NC mode relating to this
screen
None