B-63790EN/01 4.DESCRIPTION OF PARAMETERS
- 139 -
1846 Distance with which the second-stage smooth backlash compensation is
started
[Input type] Parameter input
[Data type] Integer axis
[Unit of data] Detection unit
[Valid data range] 0 to 999999999
For each axis, set a distance from the point where the direction of axis
movement is reversed to the point where the second-stage smooth
backlash compensation is started.
1847 Distance with which the second-stage smooth backlash compensation is
terminated
[Input type] Parameter input
[Data type] Integer axis
[Unit of data] Detection unit
[Valid data range] 0 to 999999999
For each axis, set a distance from the point where the direction of axis
movement is reversed to the point where the second-stage smooth
backlash compensation is terminated.
1848 First-stage smooth backlash compensation amount
[Input type] Parameter input
[Data type] Integer axis
[Unit of data] Detection unit
[Valid data range] -9999 to 9999
For each axis, set a first-stage smooth backlash compensation amount.