B-63790EN/01 4.DESCRIPTION OF PARAMETERS
- 345 -
#7 #6 #5 #4 #3 #2 #1 #0
7010
7
6
5
4
3
2
1
0
7011
7
6
5
4
3
2
1
0
7012 #7 #6 #5 #4 #3 #2 #1 #0
7013 *7 *6 *5 *4 *3 *2 *1 *0
7014 =7 =6 =5 =4 =3 =2 =1 =0
7015 ?7 ?6 ?5 ?4 ?3 ?2 ?1 ?0
7016
7
6
5
4
3
2
1
0
7017 &7 &6 &5 &4 &3 &2 &1 &0
7018
7
6
5
4
3
2
1
0
[Input type] Parameter input
[Data type] Bit
[0 to [7 : The bit pattern of the EIA or ISO/ASCII code indicating [ is set.
]0 to ]7 : The bit pattern of the EIA or ISO/ASCII code indicating ] is set.
#0 to #7 : The bit pattern of the EIA or ISO/ASCII code indicating # is set.
*0 to *7 : The bit pattern of the EIA or ISO/ASCII code indicating * is set.
=0 to =7 : The bit pattern of the EIA or ISO/ASCII code indicating = is set.
?0 to ?7 : The bit pattern of the EIA or ISO/ASCII code indicating ? is set.
@0 to @7 : The bit pattern of the EIA or ISO/ASCII code indicating @ is set.
&0 to &7 : The bit pattern of the EIA or ISO/ASCII code indicating & is set.
_0 to _7 : The bit pattern of the EIA or ISO/ASCII code indicating _ is set.
0: A corresponding bit is 0.
1: A corresponding bit is 1.
7033 M code for turning on custom macro interrupt
7034 M code for turning off custom macro interrupt
[Input type] Parameter input
[Data type] Integer
[Valid data range] From 3 through 99999999 (excluding 30, 98 and 99)
When bit 2 (MPR) of parameter No. 7002 is set to 1, that is, when a
parameter is used to set an M code for enabling/disabling interrupt-
type custom macros, set such an M code in this parameter.