B-63790EN/01 4.DESCRIPTION OF PARAMETERS
- 51 -
#7 #6 #5 #4 #3 #2 #1 #0
1010 SYC
[Input type] Parameter input
[Data type] Bit axis
#0 SYC Specifies whether to use the synchronization alignment function
based on machine coordinates in the synchronous control function.
0: Not used
1: Used
This parameter can be set for a slave axis.
When using synchronous error compensation, set this parameter to 0.
#1 RFD For rotation axis feedrate control:
0: The conventional method is used.
1: The method of feedrate specification on a virtual cicle for a
rotation axis is used.
#7 #6 #5 #4 #3 #2 #1 #0
1012 ISE ISD ISC IS
[Input type] Parameter input
[Data type] Bit axis
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
#0 ISA / #1ISC / #2 ISD / #3 ISE Increment system for each axis
Increment system #3 ISE #2 ISD #1 ISC #0 ISA
IS-A 0001
IS-B 0000
IS-C 0010
IS-D 0100
IS-E 1000