B-63790EN/01 4.DESCRIPTION OF PARAMETERS
- 237 -
5449 Magnification for three-dimensional error compensation (1-st axis)
5450 Magnification for three-dimensional error compensation (2-nd axis)
5451 Magnification for three-dimensional error compensation (3-rd axis)
[Input type] Parameter input
[Data type] Integer
[Valid data range] 1 - 100
Set a magnification for three-dimensional error compensation.
5452 Three-dimensional error compensation interval (1-st axis)
5453 Three-dimensional error compensation interval (2-nd axis)
5454 Three-dimensional error compensation interval (3-rd axis)
[Input type] Parameter input
[Data type] Real
[Unit of data] mm, inch (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 - +999999.999)
Set a three-dimensional error compensation interval.
5461 Gradient compensation point number a for each axis
5462 Gradient compensation point number b for each axis
5463 Gradient compensation point number c for each axis
5464 Gradient compensation point number d for each axis
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Integer axis
[Valid data range] From 0 through 1279 or from 0 through 3071 depending on the
number of controlled axes is less than or equal to 10 or greater than
10, respectively.
Set a gradient compensation point. A compensation point to be set
becomes a compensation number in stored pitch error compensation.