B-63790EN/01 4.DESCRIPTION OF PARAMETERS
- 199 -
4.16 WAVEFORM DIAGNOSIS FUNCTION PARAMETERS
(DATA NO. 4600 AND LATER)
4601 Output format of files
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 1
Specify the format to use when the data obtained by tracing with the
waveform diagnosis function is to be output to an external
input/output device.
0: FS15i format
1: FS15B format (old format)
NOTE
When the data obtained by tracing the contents of
memory is output, set to 0 in this parameter.
4602 Servo alarm trigger
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 1
If the trace condition is either type 2 or 3, specify whether the
occurrence of a servo alarm should be considered a trigger event.
0: The occurrence of a servo alarm is considered a trigger event.
1: The occurrence of a servo alarm is not considered a trigger event.
4603 Machine signal trigger
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 3
If the trace condition is either type 2 or 3, specify whether a machine
signal should be considered a trigger event.
0: An on machine signal is considered a trigger event.
1: An off machine signal is considered a trigger event.
2: A machine signal change is considered a trigger event.
3: A machine signal is not considered a trigger event.
4604 Trace time
[Input type] Parameter input
[Data type] Integer
[Unit of data] msec
[Valid data range] 10 - 80000
Specify the time in which data is to be traced.