B-63790EN/01 4.DESCRIPTION OF PARAMETERS
- 253 -
5701 Spindle speed permission ratio (q) at which it is assumed that the spindle
has attained the specified spindle speed
[Input type] Parameter input
[Data type] Integerspindle
[Unit of data] If parameter FLR (bit 1 of parameter No. 5808) is 0: 1.0%
If parameter FLR (bit 1 of parameter No. 5808) is 1: 0.1%
[Valid data range] If parameter FLR (bit 1 of parameter No. 5808) is 0: 1 to 50
If parameter FLR (bit 1 of parameter No. 5808) is 1: 1 to 127
This parameter specifies a spindle speed permission ratio at which the
spindle speed fluctuation detection function assumes that the spindle
has attained the specified speed.
5702 Spindle speed fluctuation ratio (r) not triggering a spindle speed fluctuation
detection alarm
[Input type] Parameter input
[Data type] Integerspindle
[Unit of data] If parameter FLR (bit 1 of parameter No. 5808) is 0: 1.0%
If parameter FLR (bit 1 of parameter No. 5808) is 1: 0.1%
[Valid data range] If parameter FLR (bit 1 of parameter No. 5808) is 0: 1 to 50
If parameter FLR (bit 1 of parameter No. 5808) is 1: 1 to 127
This parameter specifies a spindle speed fluctuation ratio not
triggering a spindle speed fluctuation detection alarm.
5711 Maximum spindle speed during rigid tapping (first stage)
5712 Maximum spindle speed during rigid tapping (second stage)
5713 Maximum spindle speed during rigid tapping (third stage)
5714 Maximum spindle speed during rigid tapping (fourth stage)
5715 Maximum spindle speed during rigid tapping (fifth stage)
5716 Maximum spindle speed during rigid tapping (sixth stage)
5717 Maximum spindle speed during rigid tapping (seventh stage)
5718 Maximum spindle speed during rigid tapping (eighth stage)
[Input type] Parameter input
[Data type] Integerspindle
[Unit of data] min
-1
[Valid data range] 0 - 999999999
These parameters specify the maximum spindle speed used for each
gear stage during rigid tapping. Issuing an S command having a
value larger than each specified value is results in an alarm.