4.DESCRIPTION OF PARAMETERS B-63790EN/01
- 86 -
1411 Arbitrary manual angle feedrate
[Input type] Parameter input
[Data type] Real
[Unit of data] mm/min, inch/min (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 - +240000.0)
Set the arbitrary manual angle feedrate for when the jogging feedrate
dial is turned to 100%. The unit of data depends on the increment
system of the basic axes.
1412 Percentage value for rapid traverse override F1
[Input type] Parameter input
[Data type] Integer
[Unit of data] %
[Valid data range] 0 - 100
Set the percentage value to use for rapid traverse override F1.
1413 Maximum number of buffered manual handle feed pulses
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 4
The permissible flow amount is set. If such a handle feed that
momentarily exceeds the rapid traverse rate is specified, the handle
pulses for the excess of the rapid traverse rate are not discarded, but
are accumulated according to the setting.
7500
2
)setting(
)rate traverserapid(
amount flow ePermissibl
×
=
Normally, 0 may be set.
1414 Magnification m of manual handle feed
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 2000
Set the magnification m for when movement selection signals MP1
and MP2 for manual handle feed are 0 and 1, respectively.
Travel amount select signal
MP4 MP2 MP1
Amount of travel
(manual handle feed)
0 0 0 Least input increment × 1
0 0 1 Least input increment × 10
0 1 0 Least input increment × m
*1
0 1 1 Least input increment × n
*1
*1 To be set in parameter No.1414.
*2 To be set in parameter No.1418.