4.DESCRIPTION OF PARAMETERS B-63790EN/01
- 216 -
5070 Minimum baud rate at which reception clock pulses are supplied from the
remote device (for the RS-422 remote buffer only)
[Input type] Setting input
[Data type] Integer
[Valid data range] 0 - 13
Boundary value at which the reception clock of the CNC is
synchronized with the host clock.
1 : 50, 2 : 100, 3 : 110, 4 : 150, 5 : 200, 6 : 300, 7 : 600. 8 : 1200,
9 : 2400, 10 : 4800, 11 : 9600, 12 : 19200, 13 : 38400 [bps]
If using the PROGRAM FILE Mate, set 13.
NOTE
At 38400 bps or higher, be sure to synchronize the
reception clock.
If the transfer rate exceeds the setting of this
parameter, the reception clock of the CNC is
synchronized with the host clock (provided that the
value of parameter No. 5073 is equal to or greater
than the value of No. 5070).
If communicating at high transmission rate using
another RS-422 interface, refer to the supplementary
manual supplied with the remote buffer for details.
5071 RS-422 I/O device type number (remote buffer)
[Input type] Setting input
[Data type] Integer
[Valid data range] 0,8
Set the type number of the host of the remote buffer.
8: PROGRAM FILE Mate
0: Type other than the above
For example, if using a personal computer, set 0.
5072 Number of RS-422 stop bits (remote buffer)
[Input type] Setting input
[Data type] Integer
[Valid data range] 1, 2
Specify the number of RS-422 device stop bits of the remote buffer.
If the number of stop bits is specified as 1, a parity bit is attached.
NOTE
If the number of stop bits is specified as 1, a parity bit
is attached.