4.DESCRIPTION OF PARAMETERS B-63790EN/01
- 174 -
2223 Number of decimal places used for displaying the actual feedrate
[Input type] Setting input
[Data type] Integer
[Valid data range] 0 to 3
Specify the number of decimal places used for displaying the actual
feedrate.
In the inch input mode, the value obtained by adding 1 to the setting is
used as the number of decimal places.
Settings
0 : In the metric input mode:
Displays the actual feedrate with no decimal places.
In the inch input mode:
Displays the actual feedrate to the first decimal place.
1 : In the metric input mode:
Displays the actual feedrate to the first decimal place.
In the inch input mode:
Displays the actual feedrate to the second decimal place.
2 : In the metric input mode:
Displays the actual feedrate to the second decimal place.
In the inch input mode:
Displays the actual feedrate to the third decimal place.
3 : In the metric input mode:
Displays the actual feedrate to the third decimal place.
In the inch input mode:
Displays the actual feedrate to the fourth decimal place.
2231 Axis number on the load meter for the first servo axis
2232 Axis number on the load meter for the second servo axis
2233 Axis number on the load meter for the third servo axis
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - Max axes
Specify the axis number to be displayed on the load meter for the
servo axis.
2234 Rated load to be displayed on the load meter of the 1st analog spindle motor
[Input type] Parameter input
[Data type] Integer
[Valid data range] From 0 through 128
Specify the rated load of the motor corresponding to the load meter.
Example) When the load meter is at 100% and the input to the AD
converter is 6 [V],
Set 128 x 6 [V]/10 [V] = 77.