B-63790EN/01 4.DESCRIPTION OF PARAMETERS
- 39 -
0040 Serial port channel for Remote Diagnostic Function
[Input type] Setting input
[Data type] Integer
[Valid data range] 1 - 3
Selection of serial port channel for Remote Diagnostic Function.
1: RS-232-C Serial port1 (JD5A)
2: RS-232-C Serial port2 (JD5B)
3: RS-232-C Serial port3 (JD36A)
17: Modem card (PCMCIA card slot on the LCD unit)
0042 Password 1 for Remote Diagnostic Function
[Input type] Locked parameter
[Data type] Integer
[Valid data range] 0 - 99999999
0043 Keyword 1 for Remote Diagnostic Function
[Input type] Locked parameter
[Data type] Integer
[Valid data range] 0 - 99999999
0044 Password 2 for Remote Diagnostic Function
[Input type] Locked parameter
[Data type] Integer
[Valid data range] 0 - 99999999
0045 Keyword 2 for Remote Diagnostic Function
[Input type] Locked parameter
[Data type] Integer
[Valid data range] 0 - 99999999
0046 Password 3 for Remote Diagnostic Function
[Input type] Locked parameter
[Data type] Integer
[Valid data range] 0 - 99999999
0047 Keyword 3 for Remote Diagnostic Function
[Input type] Locked parameter
[Data type] Integer
[Valid data range] 0 - 99999999
Parameters (No.0042, 0044, 0046) set passwords for using the remote
diagnosis function.
With the remote diagnostic function, three types of passwords are
available for protecting data. These passwords help to prevent