B-63790EN/01 4.DESCRIPTION OF PARAMETERS
- 227 -
5280 Maximum value of the operating range of the 1-st position switch (PSW101)
5281 Maximum value of the operating range of the 2-nd position switch (PSW102)
5282 Maximum value of the operating range of the 3-rd position switch (PSW103)
5283 Maximum value of the operating range of the 4-th position switch (PSW104)
5284 Maximum value of the operating range of the 5-th position switch (PSW105)
5285 Maximum value of the operating range of the 6-th position switch (PSW106)
5286 Maximum value of the operating range of the 7-th position switch (PSW107)
5287 Maximum value of the operating range of the 8-th position switch (PSW108)
5288 Maximum value of the operating range of the 9-th position switch (PSW109)
5289 Maximum value of the operating range of the 10-th position switch (PSW110)
[Input type] Parameter input
[Data type] Real
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 - +999999.999)
Set the maximum value of the operating range of the first to tenth
position switches.
NOTE
1 For a diameter-specified axis, use radius values to
specify the parameters used to set the maximum
and minimum values of an operating range.
2 The position switch function is enabled upon
completion of reference position return.