B-63790EN/01 4.DESCRIPTION OF PARAMETERS
- 75 -
1243 Coordinates of the fourth reference position in the machine coordinate
system
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 - +999999.999)
Set the coordinates of the fourth reference position in the machine
coordinate system.
1244 Floating reference position in G30.1
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 - +999999.999)
Set the coordinates of the floating reference position in the machine
coordinate system.
1260 Movement of one rotation of a rotary axis
NOTE
After this parameter has been set, the power must be
off turned off then back on for the setting to become
effective.
[Input type] Parameter input
[Data type] Real axis
[Unit of data] degree
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 0 or positive 9 digit of minimum unit of data (refer to the standard
parameter setting table (B) )
(When the increment system is IS-B, 0.0 - +999999.999)
Set the value of movement of one rotation of a rotary axis.