4.DESCRIPTION OF PARAMETERS B-63790EN/01
- 154 -
#2 PDT Specifies axis selection signals used for the simultaneous start
command for the PMC axis control function.
0: Use the FDxX15 to FDxX0 signals.
1: Use the DTxX31 to DTxX0 signals.
#4 D3A In three-dimensional coordinate conversion mode, axis movement
signals are:
0: Output to the program command axis.
1: Output to the axis of travel.
#7 SKE Specifies which skip signal is to be used for PMC axis control as
follows:
0: SKIP1 (same skip signal as that for the CNC)
1: PCSKP (signal specific to PMC axis control)
#7 #6 #5 #4 #3 #2 #1 #0
2007 CT
G5S EWN
[Input type] Parameter input
[Data type] Bit
#1 EWN When a search by workpiece number is made, a workpiece number is
specified by using:
0: Workpiece number search signals (WN1 to WN16)
(A number from 1 to 31 can be specified.)
1: Extended workpiece number search signals (EWN0 to EWN26)
(A number from 1 to 99999999 can be specified.)
#3 G5S In binary input operation mode, single-block stop is:
0: Disabled.
1: Enabled.
#4 CTR At power-on, the status of the toggle-type custom soft key function
signal (CTSF) immediately before the previous power-off is:
0: Not restored.
1: Restored.
2010 Delay time of the MF, SF, TF, or BF strobe signal
[Input type] Parameter input
[Data type] Integer
[Unit of data] msec
[Valid data range] 0 - 32767
Specify the time waited before the MF, SF, TF, or BF signal is sent
after the M, S, T, or B code is sent.
M, S, T, B code
MF, SF, TF, BF signal
Dela
time