B–63833EN–1/02
4. REFERENCE POSITION ESTABLISHMENT
209
When the butt–type reference position setting function is used, this
parameter sets the feedrate used to hit the stopper on an axis for a second
time.
7185
Withdrawal feedrate (common to the first and second butting operations)
in butt–type reference position setting)
[Data type] Word axis
Valid data range
Increment system Unit of data
IS–A, IS–B IS–C
Millimeter machine 1 mm/min 30–15000 30–12000
Inch machine 0.1 inch/min 30–6000 30–4800
When the butt–type reference position setting function is used, this
parameter sets the feedrate used for withdrawal along an axis after the
mechanical stopper has been hit.
7186 Torque limit value in butt–type reference position setting
[Data type] Byte axes
[Unit of data] %
[Valid data range] 0 to 100
This parameter sets a torque limit value in butt–type reference position
setting.
NOTE
When 0 is set in this parameter, 100% is assumed.
Number Message Contents
000 PLEASE TURN OFF POWER A parameter which requires the
power off was input, turn off
power.
NOTE
This function is supported only when an absolute–position
detector is installed.
[Unit of data]
[Valid data range]
Alarm and message
Note