B–63833EN–1/02
11. PROGRAM COMMAND
639
#7 #6 #5 #4 #3 #2 #1 #0
GSC3401 GSB
[Data type] Bit
GSB, GSC The G code system is set.
GSC GSB G code
0 0 G code system A
0 1 G code system B
1 0 G code system C
#7 #6 #5 #4 #3 #2 #1 #0
3402 CLR G91 G01
[Data type] Bit
G01 Mode entered when the power is turned on or when the control is cleared
0 : G00 mode (positioning)
1 : G01 mode (linear interpolation)
G91 When the power is turned on or when the control is cleared
0 : G90 mode (absolute command)
1 : G91 mode (incremental command)
CLR Reset button on the CRT/MDI panel, external reset signal, reset and
rewind signal and emergency stop signal
0 : Cause reset state.
1 : Cause clear state.
Number Message Description
010
IMPROPER G–CODE An unusable G code or G code correspond-
ing to the function not provided is specified.
Modify the program.
Parameter
Alarm and message