B–63833EN–1/02
12. DISPLAY/SET/EDIT
723
This function displays the integrated power–on time, the integrated cycle
operation time, the integrated cutting time and timer (started by an input
signal from PMC) on the screen. The integrated cycle operation time, the
integrated cutting time and timer can be altered and preset, by the
operator.
In addition to the above, this function displays the count of the total
number of parts machined, the number of parts required and the number
of completed parts on the screen. Each time M02, M30 or a parameter set
M code is executed, the count of the total number of parts machined and
the number of parts completed is incremented by 1.
If a program is prepared so as to execute M02, M30 or a parameter set M
code each time one part machining is completed, the number of parts
machined can be counted automatically.
If the count of the number of parts machined reaches the number of parts
required, a signal is output to the PMC side.
It is possible for the operator to change and preset the number of parts
required and the number of parts completed.
[Classification] Output signal
[Function] Reports to the PMC that the specified number of parts have been
machined.
[Output condition] The PRTSF signal is set to 1 when:
@ Machining of the specified number of parts has been completed.
When the required number of parts is zero, this signal is not set.
The PRTSF signal is set to 0 when:
@ Machining of the specified number of parts has not yet been
completed.
@ The system is reset.
12.1.11
Run Hour and Parts
Count Display
General
Signal
Target part count
reached signal
PRTSF<F062#7>