12. DISPLAY/SET/EDIT
B–63833EN–1/02
774
OPERATOR’S MANUAL
(M series) (B–63844EN)
III.9.9 PASSWORD FUNCTION
Series 0i–B
OPERATOR’S MANUAL
(T series) (B–63834EN)
III.9.9 PASSWORD FUNCTION
OPERATOR’S MANUAL
(M series) (B–63864EN)
III.9.9 PASSWORD FUNCTION
Series 0i Mate–B
OPERATOR’S MANUAL
(T series) (B–63854EN)
III.9.9 PASSWORD FUNCTION
Editing a program while executing another program is called background
editing. The method of editing is the same as for ordinary editing
(foreground editing).
A program edited in the background should be registered in foreground
program memory.
During background editing, all programs cannot be deleted at once.
Number Message Description
??? BP/S alarm BP/S alarm occurs in the same number
as the P/S alarm that occurs in ordinary
program edit. (070, 071, 072, 073, 074
085,086,087 etc.)
140 BP/S alarm It was attempted to select or delete in
the background a program being se-
lected in the foreground.
Use background editing correctly.
239 BP/S alarm Background editing was performed
while the external punch was being
executed in external I/O device control.
240 BP/S alarm Background editing was done while in
MDI operation.
NOTE
Alarm in background edit is displayed in the key input line
of the background edit screen instead of the ordinary alarm
screen and is resettable by any of the MDI key operation.
Reference item
12.2.5
Background Editing
General
Alarm and message