11. PROGRAM COMMAND
B–63833EN–1/02
688
#7 #6 #5 #4 #3 #2 #1 #0
*BECLPG038 *BEUCP
#7 #6 #5 #4 #3 #2 #1 #0
F061 BCLP BUCLP
#7 #6 #5 #4 #3 #2 #1 #0
1006 ROSx ROTx
[Data type] Bit axis
ROTx, ROSx Define linear or rotation axis
ROSx ROTx Description
0 0 Linear axis
@ Inch/metric conversion is done.
@ All coordinate values are linear axis type.
(Not rounded in 0 to 360_)
@ Stored pitch error compensation is linear axis type (Refer to pa-
rameter No. 3624)
0 1 Rotation axis (A type)
@ Inch/metric conversion is not done.
@ Machine coordinate values are rounded in 0 to 360_
Rounding of absolute coordinate values and relative coordinate
values is decided by parameter No. 1008#0 and #2.
@ Stored pitch error compensation is of the rotation type. (Refer
to parameter No. 3624)
@ Automatic reference position return (G28, G30) is done in the
reference position return direction and the move amount does
not exceed one rotation.
1 0
Setting is invalid (unused)
1 1 Rotation axis (B type)
@ Inch/metric conversion is not done.
@ Machine coordinate values is of linear axis type (i.e. not rounded
in 0 to 360_).
@ Rounding of absolute coordinate values and relative coordinate
values is decided by parameter No. 1008#0 and #2.
@ Stored pitch error compensation is of linear axis type (Refer to
parameter No. 3624).
@ Cannot be used with the rotation axes roll over function and the
index table indexing function (M series).
Signal address
Parameter
D Setting linear or rotation
axis