B–63833EN–1/02
14. MEASUREMENT
869
5020 Tool offset number used for the input of tool offset value measured B
[Data type] Byte
[Valid data range] 0 to the number of tools to be compensated.
Set tool offset number used for the input of tool offset value measured B
function (i.e. when workpiece coordinate system shift value is set). (The
tool offset number corresponding to the measured tool shall be set in ad-
vance.) This parameter is valid when the tool offset number is not selected
automatically (QNI, #5 of parameter 5005, is zero).
5021 Number of pulse interpolation cycles memorized prior to contacting the touch sensor
[Data type] Byte
[Unit of data] Interpolation cycle
[Valid data range] 0 to 8
This parameter sets the number of pulse interpolation cycles to be
memorized until the operator manually touches the tool with a
one–contact input touch sensor when the tool offset measurement value
direct input B function is used.
If 0 is set for this parameter, the specification of 8 (maximum allowable
value) is assumed.
NOTE
This parameter is enabled when the TS1 parameter (bit 3
of parameter No.5004) is set to 1.
#7
5051
#6 #5 #4 #3 #2 #1
2AT
#0
2NR
[Data type] Bit
2NR When the tool setter function for 1–turret, 2–spindle lathes is used:
0 : One touch sensor is used for both main spindle 1 and main spindle 2.
1 : Two touch sensors are used for both main spindle 1 and main spindle 2.
2AT When a workpiece reference point offset value is set in workpiece
coordinate system memory with the tool setter function for 1–turret,
2–spindle lathes:
0 : The value is set at the current cursor position.
1 : A memory is automatically selected. (The workpiece coordinate
system memory set in parameter No.5054 or No.5055 is selected.)
5053 Bias for tool offset numbers for measured tool offset value setting
[Data type] Byte
[Unit of data] Number
[Valid data range] 1 to maximum tool offset count
When the tool setter function for 1–turret, 2–spindle lathes is used, this
parameter allocates tool offset numbers for measured tool offset
measurement values to spindle 1 and spindle 2.