B–63833EN–1/02
1. AXIS CONTROL
81
Units digit in the parameter for the first axis
→ Set the axis number for the master axis when the first axis is used
as a slave axis.
Tens digit in the parameter for the first axis
→ Set the axis number for the master axis when the second axis is used
as a slave axis.
Units digit in the parameter for the second axis
→ Set the axis number for the master axis when the third axis is used
as a slave axis.
Tens digit in the parameter for the second axis
→ Set the axis number for the master axis when the fourth axis is used
as a slave axis.
Number Tens digit Units digit
First
Second
Second axis
Fourth axis
First axis
Third axis
NOTE
The axis number settings are: 0 for the first axis, 1 for the
second axis, 2 for the third axis, and so on.
Example) To set the 3rd axis as the master axis and the 4th axis to the slave
axis, set as follows:
No. 8311
1st axis 00
2nd axis 20
3rd axis 00
4th axis 00
8312 Enabling/disabling mirror image in synchronous control
[Data type] Byte axis
[Valid data range] –127 to +128
This parameter sets the mirror image function. When 100 or a greater
value is set with this parameter, the mirror image function is applied to
synchronous control. Set this parameter to the slave axis.
Example: To establish reversed synchronization when using the third axis
as the master axis and the fourth axis as the slave axis, set parameter No.
8312 as follows:
Parameter No. 8312 (first axis) = 0
Parameter No. 8312 (second axis) = 0
Parameter No. 8312 (third axis) = 0
Parameter No. 8312 (fourth axis) = 100