13. INPUT/OUTPUT OF DATA
B–63833EN–1/02
782
Stop bit and other data
Number specified for the input/
output device
Baud rate
Stop bit and other data
Number specified for the input/
output device
Baud rate
Stop bit and other data
Number specified for the input/
output device
Baud rate
I/ O CHANNEL
=0 : Channel1
=1 : Channel1
=2 : Channel2
Specify a channel for an in-
put/output device.
I/O CHANNEL=1
(channel 1)
0020
0101
0102
I/O CHANNEL=0
(channel 1)
0103
0111
0112
0113
0121
0122
I/O CHANNEL=2
(channel 2)
0123
I/O CHANNEL
Input/output channel number (parameter No.0020)
↓
Fig.13.1 I/O Device Interface Settings
0024 Port for communication with the PMC ladder development tool (FAPT LADDER–III)
This parameter can be entered on the setting screen
[Data type] Byte
This parameter sets the port to be used for communication with the PMC
ladder development tool (FAPT LADDER–III).
0 : According to the setting on the PMC online screen
1 : RS–232C serial port 1 (JD36A)
2 : RS–232C serial port 2 (JD36B)
10 : High–speed interface (HSSB(COP7) or Ethernet)
11 : High–speed interface or RS–232–C serial port 1
12 : High–speed interface or RS–232–C serial port 2
#7
ENS0100
#6
IOP
#5
ND3
#4 #3
NCR
#2
CRF
#1
CTV
#0
[Data type] Bit
CTV: Character counting for TV check in the comment section of a program.
0 : Performed
1 : Not performed
CRF EOB (end of block) to be output in the ISO code:
0: Depends on the setting of bit 3 (NCR) of parameter No. 100.
1: is “CR”“LF”.
(1) Parameters
Common to all
Channels