B–63833EN–1/02
9. SPINDLE SPEED FUNCTION
518
G027 *SSTP3 *SSTP2 *SSTP1 SWS3 SWS2 SWS1
#7 #6 #5 #4 #3 #2 #1 #0
PC2SLCG028 GR2 GR1
G029 *SSTP GR31 GR21
G031
R08IG032 R07I R06I R05I R04I R03I R02I R01I
SINDG033 SSIN SGN R12I R11I R10I R09I
R08I2G034 R07I2 R06I2 R05I2 R04I2 R03I2 R02I2 R01I2
SIND2G035 SSIN2 SGN2 R12I2 R11I2 R10I2 R09I2
R08I3G036 R07I3 R06I3 R05I3 R04I3 R03I3 R02I3 R01I3
SIND3G037 SSIN3 SGN3 R12I3 R11I3 R10I3 R09I3
#7 #6 #5 #4 #3 #2 #1 #0
F038 ENB3 ENB2
The parameters for the 1st spindle and the 1st position coder are the same
as usual. This section describes the parameters which are added by the
multi–spindle control function.
#7 #6 #5 #4 #3 #2 #1 #0
3701 SS2
[Data type] Bit
SS2 In serial spindle control, the second spindle is:
0 : Not used.
1 : Used.
NOTE
This parameter is valid, when the spindle serial output
function is provided and parameter ISI(bit 1 of parameter
No.3701)is 0.
1 Confirmation of connection of the second serial spindle
amplifier, and communication with it
2 Control of the second spindle during asynchronous
control (SIND2)
When this parameter is set, it is also necessary to set the
serial spindle parameter for the second spindle.
Parameter setting
SS2
(No.3701#4)
Serial spindles to be used
0 First spindle only
1 First and second spindles
Signal address
Parameter