A.PARAMETERS APPENDIX B-63874EN/05
- 748 -
A.2.2 Parameters for Operations in General
#7 #6 #5 #4 #3 #2 #1 #0
14700 MGI CS2 CS1 PWD
PWD 0 : When the power is turned on, the system is not switched to the
Manual Guide screen.
1 : When the power is turned on, the system is switched to the Manual
Guide screen.
CS1= 0, CS2 = 0 : When the power is turned on, the custom screen is not displayed.
CS1= 1, CS2 = 0 : When the power is turned on, Custom Screen 1 (AUX) is displayed.
CS1= 0, CS2 = 1 : When the power is turned on, Custom Screen 3 (MCR) is displayed.
CS1= 1, CS2 = 1 : When the power is turned on, Custom Screen 2 (MENU) is displayed.
MGI 0 : MANUAL GUIDE i is enabled.
1 : MANUAL GUIDE i is disabled.
#7 #6 #5 #4 #3 #2 #1 #0
14701 PCK CLP2 CLP1 FSP FMP FSE
FSE 0 : Tool post 1 cannot be used with spindle 2.
1 : Tool post 1 can be used with spindle 2.
NOTE
FSE is available in the case of No.14702 SUB(#1)
= 1 only.
FMP 0 : Tool post 1 is placed above spindle 1.
1 : Tool post 1 is placed under spindle 1.
FSP 0 : Tool post 1 is placed above spindle 2.
1 : Tool post 1 is placed under spindle 2.
NOTE
FSP is available in the case of No.14702 SUB(#1)
= 1 and No.14701 FSE(#1) = 1 only.
CLP1= 0, CLP2 = 0 : The size of the clipboard is set to 1024 bytes.
CLP1= 1, CLP2 = 0 : The size of the clipboard is set to 2048 bytes.
CLP1= 0, CLP2 = 1 : The size of the clipboard is set to 4096 bytes.
CLP1= 1, CLP 2 = 1 : The size of the clipboard is set to 8192 bytes.
PCK 0 : Process List Editing Function : The soft-key [ADD /] and [DEL /] for
program check function for each spindle are not displayed.
1 : Process List Editing Function : The soft-key [ADD /] and [DEL /] for
program check function for each spindle are displayed.
FMP=1
FSP=1
1
2
FMP=0
FSP=0