A.PARAMETERS APPENDIX B-63874EN/05
- 770 -
A.2.18 Settings for Tool Management Functions
These parameters are for the settings for tool management functions.
#7 #6 #5 #4 #3 #2 #1 #0
14823 STS TLD LIA LIF TMG MSR TOF ORT
ORT 0 : The screen for associating a tool number with a compensation number
is not displayed.
1 : The screen for associating a tool number with a compensation number
is displayed.
TOF 0 : The per-tool-number tool offset setting screen is not displayed.
1 : The per-tool-number tool offset setting screen is displayed.
MSR 0 : The compensation type, tool number, and group number input fields
are not displayed on the measurement screen.
1 : The compensation type, tool number, and group number input fields
are displayed on the measurement screen.
TMG 0 : The tool management data setting screen is not displayed.
1 : The tool management data setting screen is displayed.
LIF 0 : The tool life management data setting screen is not displayed.
1 : The tool life management data setting screen is displayed.
LIA 0 : The screen of Tool Life Data List is not displayed.
1 : The screen of Tool Life Data List is displayed.
TLD 0 : The soft-key for changing screen from Manual Guide i to Tool
Management Data Table is not displayed.
1 : The soft-key for changing screen from Manual Guide i to Tool
Management Data Table is displayed.
STS 0 : When a compensation type is specified, the compensation type is not
displayed in the status display area.
1 : When a compensation type is specified, the compensation type is
displayed in the status display area.
14824 OFSRELTL
OFSRELTL : Start compensation number (0 to 999) to be associated with a tool
number.
14825 OFSTYPNO
OFSTYPO : Number of compensation types (0 to 9)