2.CONFIGURATION FANUC AC SERVO AMPLIFIER β series B-65232EN/03
- 130 -
Table 2.5(d) Unit types and specifications (2)
Classification Name Application Specification
Type A: For applications where the sum of the rated motor
powers does not exceed 5.4 kW
A81L-0001-0083#3C
Type B: For applications where the sum of the rated motor
powers does not exceed 10.5 kW
A81L-0001-0101#C
Basic
AC line filter
(Note 1)
Type C: For applications where the sum of the rated motor
powers does not exceed 23 kW
A81L-0001-0102
Type SAE : Capacity 2.2kVA A80L-0022-0005
Type SBE : Capacity 3.5kVA A80L-0024-0006
Type SCE : Capacity 5.0kVA A80L-0026-0003
Power
transformer for
export
(Note 2)
Type SDE : Capacity 7.5kVA A80L-0028-0001
30Ω/20W
at natural cooling
For SVU-4, SVU-12, SVU-20 A06B-6093-H401
30Ω/100W
at natural cooling
For SVU-4, SVU-12, SVU-20 A06B-6093-H402 (Note 3)
16Ω/200W
at natural cooling
For SVU-40, SVU-80 A06B-6089-H500
16Ω/800W
with cooling fan motor
For SVU-40, SVU-80 A06B-6089-H713
Separated
regenerative
discharge unit
(Caution)
16Ω/1200W
with cooling fan motor
For SVU-40, SVU-80 A06B-6089-H714
Option
Fan adapter
With forced air cooling
(Note 4)
For SVU-40, SVU-80 A06B-6078-K002
CAUTION
A separated regenerative discharge unit must be used when the amount of
regenerative energy produced by the motor exceeds a specified value because of a
high load inertia of frequent acceleration/deceleration.
Refer to Chapter 4 "Separated regenerative discharge unit" for details of
regenerative discharge unit. For information about connections, see Part V,
"CONNECTION". An incorrect connection can damage the amplifier. Care must be
taken.
NOTE
1 An AC line filter must be used to suppress the influences of high-frequency noise on
the power supply.
When a power transformer (insulation type) is used because a power supply voltage
within the specified range is not available, this AC line filter is not necessary. If the
use of this AC line filter fails to fully satisfy EMC requirements the use of a
commercially available noise filter is recommended.
2 At single-phase power input, it is not necessary.
If the line voltage is higher than 200/220/230 VAC, use a power transformer. When
a transformer is used, as AC line filter usually becomes unnecessary, however in
case that requirements of EMC standard are still not satisfied, AC line filter will be
needed.
3 A06B-6093-H402 contains a connector kit for connection with a β series amplifier as
a standard accessory.