B-65232EN/03 CONNECTION4.DETAILS OF CABLE CONNECTIONS
- 241 -
[Receptacle housing]
Receptacle housings with two key types are available. Use a
receptacle housing with the key type suitable for the servo amplifier.
Model number of
receptacle housing
Key specification
Applicable
models
Remarks
1318095-2
Wrong insertion
protection key
SVU-4, SVU-20 (*1)
1-917807-2 XX SVU-40, SVU-80
(*1) The key-less receptacle housings (175362-1, 175363-1) are also
usable. However, the use of the receptacle housings with the
specifications above is recommended.
[Receptacle contact]
Receptacle contacts are available for two wire diameter ranges of a
cable. Use a receptacle contact suitable for the wire diameter of the
cable used.
Applicable models : SVU-4, SVU-20
Model number of
receptacle contact
Wire size
(mm
2
)
Wire size
AWG
Insulation
coating
outer
diameter
(mm)
Model
number of
manual
tool
M size 1-175217-2 0.2- 0.5 24/22/20 1.2-2.6 91559-1
L size 1-175218-2 0.5- 1.25 20/18/16 1.8-2.8 91558-1
Applicable models : SVU-40, SVU-80
Model number of
receptacle contact
Wire size
(mm
2
)
Wire size
AWG
Insulation
coating
outer
diameter
(mm)
Model
number of
manual
tool
S size 316040-2 1.23 – 2.27 16/14 3.0-3.8 0-234170-1
M size 316041-2 3.08 – 5.50 12/10 4.0-5.2 0-234171-1