11.EXTERNAL PULSE INPUT (ONLY FOR I/O Link INTERFACE) CONNECTION B-65232EN/03
- 296 -
For calculation, assume that the power supply current of the manual
pulse generator is 0.1 A.
When making a calculation, include the length of the K24 cable in the
cable length.
To one manual pulse generator, multiple (up to six) units of the
FANUC servo amplifier unit β series can be connected. In this case,
prepare one manual pulse generator adapter for each unit of the
FANUC servo amplifier unit β series. A unit of the FANUC servo
amplifier unit β series can be connected with a manual pulse
generator adapter in the same way as described in Subsection 8.2.2,
"K24 Cable Connection ". JA54(3) and JA54(4) are signals used to
connect multiple units of the FANUC servo amplifier unit β series.
For details, refer to Subsection 8.1.3, "Connection with Multiple
Power Mate Units" in "FANUC Power Mate-MODEL E Connection
and Maintenance Manual (B-62115E)". One unit of the FANUC servo
amplifier unit β series connected with a manual pulse generator
adapter via cable K24 corresponds to one Power Mate unit.