8.DETAILS OF CABLE CONNECTIONS CONNECTION B-65232EN/03
- 276 -
8.5 K7 AND K8 CABLES CONNECTION
When separated regenerative discharge unit is used
Separated regenerative discharge
unit
β series amplifier
CX23-B1 (RC)
CX23-B2 (RE)
Cable specification :
Vinyl cabtyre cable, JIS C 3312, 2 conductors
Conductor 3.5 mm
2
Housing : 2-917807-2
Contact : 316041-2
Applicable power line range : 3.5mm
2
to 5.5mm
2
Crimping terminal : 5.5-4
Manufacture : tyco Electronics AMP
CX20-1 (TH1)
CX20-3 (TH2)
Cable specification :
Vinyl cabtyre cable, JIS C 3312, 2 conductors
Conductor 0.75 mm
2
Housing : 2-178288-3
Contact : 1-175218-5
Applicable power line range : 0.5mm
2
to 1.25mm
2
Crimping terminal : 1.25-4