B-65232EN/03 FANUC AC SERVO AMPLIFIER β series 2.CONFIGURATION
- 133 -
Table 2.5(f) Unit types and specifications (for SVU-40, SVU-80)
Classification Name Application Specification
Connector
(common)
CX21: For input power line Crimp type A06B-6093-K311
Connector
(common)
CX22: For motor power line
(cross-sectional area of wire is under 3.5 mm
2
)
Crimp type A06B-6093-K312
Connector
(common)
CX22: For motor power line
(cross-sectional area of wire is under 3.5 mm
2
)
Crimp type A06B-6093-K313
Connector
(common)
CX20, CX23:For regenerative discharge resistor
(When separate regenerative discharge resistor is
not used.)
Crimp type
A06B-6093-K314
(Note 1)
Connector
(common)
CX20, CX23: For regenerative discharge resistor
(When separate regenerative discharge resistor is
used.)
Crimp type
A06B-6093-K315
(Note 1)
Connector
(common)
CX19A/B: For 24 VDC input/output connector Crimp type A06B-6093-K316
Connector
(common)
CX19A/B: For 24 VDC input/output connector Crimp type
A06B-6093-K317
(Note 2)
Connector
(common)
JF1 : For pulse coder F/B cables Solder type A06B-6073-K214
Fuse
(common)
For protecting control power 24 VDC from a short-circuit A06B-6073-K250
Connector Solder type A06B-6073-K212
(PWM, FSSB)
JX5 : For ESP signal
Crimp type A06B-6073-K213
Connector Solder type A06B-6073-K212
(PWM)
JS1B : NC-SVU command cable
Crimp type A06B-6073-K213
Connector Solder type A06B-6073-K212
(I/O Link)
JD1A : For I/O Link
Crimp type A06B-6073-K213
Connector Solder type A06B-6073-K212
(I/O Link)
JD1B : For I/O Link
Crimp type A06B-6073-K213
Connector Solder type A06B-6073-K212
(I/O Link)
JA35 : For built-in DI input cable
Crimp type A06B-6073-K213
Basic
Connector
(I/O Link)
JA34 : For external pulse input cable A06B-6073-K214
Connector
(common)
CX5X, Y : For battery A06B-6093-K303
Battery case
(common)
For absolute pulse coders. Connection method 1 (Note 3) A06B-6093-K002
Battery
(common)
For absolute pulse coders. Connection method 1 (Note 3) A06B-6093-K001
Battery case
(common)
For absolute pulse coders. Connection method 2 (Note 3) A06B-6050-K060
Battery
(common)
For absolute pulse coders. Connection method 2 (Note 3) A06B-6050-K061
Lightning
surge absorber
Not complying with the standard (Note 4) A06B-6077-K141
Option
(common) Complying with the standard (Note 4) A06B-6077-K142
The terms "PWM," " I/O Link," and "common" used in the Name column indicate what interface to be used.
PWM : The PWM interface is used.
I/O Link : The I/O Link interface is used.
Common : The FSSB interface, I/O Link interface, and PWM interface can be used.