B--63003EN--1/02
12. DISPLAY/SET/EDIT
1039
[Classification] Output signal
[Function] Reports to the PMC that the specified number of parts have been
machined.
[Output condition] The PRTSF signal is set to 1 when:
⋅ Machining of the specified number of parts has been completed.
When 0 (infinity) is set as the required number of parts, this signal is
not output.
The PRTSF signal is set to 0 when:
⋅ Machining of the specified number of parts has not yet been
completed.
⋅ The system is reset.
[Classification] Input signal
[Function] The CNC has an integrating meter which is started by an input signal from
the PMC, as well as integrating meters for counting the automatic
operation time and counting cutting time. The count for this integrating
meter can be displayed on the screen. The count can be preset by MDI
operation.
[Operation] When the signal is set to 1, the integrating meter starts counting.
#7 #6 #5 #4 #3 #2 #1 #0
G053 TMRON
#7 #6 #5 #4 #3 #2 #1 #0
PRTSFF062
Signal
Target part count
reached sign al
PRTSF<F062#7>
General--purpose
integrating meter start
signal
TMRON <G053#0>
Signal address