B--63003EN--1/02
7. FEEDRATE CONTROL/ACCELERATION
AND DECELERATION CONTROL
535
1450
Change of feedrate for one graduation on the manual pulse
generator during F1 digit feed
[Data type] Byte
[Valid data range] 1to127
Set the constant that determines the changein feedrate as the manual pulse
generator is rotated one graduation during F1-digit feed.
F =
Fmaxi
100n
α
(where, i=1 or 2)
In the above equation, set n. That is, the number of revolutions of the
manual pulse generator, required to reach feedrate Fmaxi is obtained.
Fmaxi refers to the upper limit of the feedrate for an F1-digit feed
command, and set it in parameter 1460 or 1461.
Fmax1: Upper limit of the feedrate for F1 to F4 (parameter 1460)
Fmax2: Upper limit of the feedrate for F5 to F9 (parameter 1461)
1451 Feedrate for F1 digit command F1
1452 Feedrate for F1 digit command F2
1453 Feedrate for F1 digit command F3
1454 Feedrate for F1 digit command F4
1455 Feedrate for F1 digit command F5
1456 Feedrate for F1 digit command F6
1457 Feedrate for F1 digit command F7
1458 Feedrate for F1 digit command F8
1459 Feedrate for F1 digit command F9
Input for setting is enabled.
[Data type] Two--word
Valid data range
ncrement system
n
to
ata
I S --- A , I S --- B I S --- C
Millimeter machine 0.1 mm/min 6 -- 150000 6 -- 120000
Inch machine 0.01 inch/min 6 -- 60000 6 -- 48000
Rotation axis 0.1 deg/min 6 -- 150000 6 -- 120000
Set Feedrates for F1-digit feed commands F1 to F9.
When an F1-digit feed command is executed, as the feedrate is changed by
turning the manual pulse generator, these parameter values also change
accordingly.
Parameter
[Unitofdata]
[Valid data range]