B--63003EN--1/02
2. PREPARATIONS FOR OPERATION
231
When the tool tries to exceed a stored stroke check, an alarm is displayed
and the tool is decelerated and stopped.
When the tool enters a forbidden area and an alarm is generated, the tool
can be moved in the reverse direction from which the tool came.
Parameters (Nos. 1320, 1321 or Nos. 1326, 1327) set boundary. Outside
the area of the set checks is a forbidden area. The machine tool builder
usually sets this area as the maximum stroke.
[Classification] Input signal
[Function] Selects stroke check 1--I (parameter Nos. 1320 and 1321) or stroke check
1--II (parameter Nos. 1326 and 1327).
[Operation] When this signal is set to 1, the control unit operates as follows:
-- Checks stroke check 1 on the basis of parameter Nos. 1326 and 1327,
instead of parameter Nos, 1320 and 1321.
[Classification] Input signal
[Function] Change the values of the parameters governing the strokecheck (1320 and
1321).
[Operation] When these signals are set to 1, the control unit operates as follows:
-- Change the stored checks, set with parameter Nos. 1320 and 1321,
to the machine coordinates when the signals are input.
[Classification] Input signal
[Function] Selects whether the stored stroke check 1 are checked.
[Operation] When this signal is set to 1, the control unit operates as follows:
-- Does not check the stored stroke check 1.
2.3.2
Stored Stroke Check 1
General
Signal
Stored stroke check
select sig n al EXLM
<G007#6>
Stroke ch eck external
setting signals +LM1 to
+LM8 <G110> and --LM1
to --LM8 <G112> (M
series)
Stroke ch eck release
signal RLSOT <G007#7>
(M series)