8/9
PAGEEDT.
DATE
DESIGN
DESCRIPTION
TITLE
No.
FANUC Series 16i/18i/21i/20i/160i/180i/210i-MODEL A
CONNECTION MANUAL (FUNCTION)
Concerning the addition of Look-Ahead Bell-Shaped
Acceleration/Deceleration Before Interpolation Time
Constant Change Function
B-63003EN-1
02-08 01 01.08.29 Newl
Re
istered
7066 Acceleration/deceleration reference speed for the bell-shaped
acceleration/deceleration time constant change function
in AI Contour control mode or AI Nano contour control mode
[Input section] Parameter input
[Data type] 2 word
[Unit of data]
[Minimum data unit]
[Valid data range] Acceleration/deceleration reference speed for the bell-shaped
acceleration/deceleration time constant change function
in AI Contour control mode or AI Nano contour control mode is set on this
parameter. When the input unit is changed, this parameter must be
changed.
In AI High Precision Contour control mode or AI Nano High Precision
Contour control mode, parameter No.19520 should be set.
#7 #6 #5 #4 #3 #2 #1 #0
19501 BCG
[Input section] Parameter input
[Data type] Bit type
# 6 BCG The bell-shaped acceleration/deceleration time constant change function in
AI High Precision Contour control mode or AI Nano High Precision contour
control mode is:
0: Disabled.
1: Enabled.
In AI contour control mode or AI Nano contour control mode, parameter
BCG (No. 7055 bit 3) should be set.
Increment system Unit of data Valid range
IS-B IS-C
Millimeter input 1 mm/min 0 - 600000 0 – 60000
Inch input 0.1 inch/min 0 - 600000 0 - 60000