B--63003EN--1/02
3. MANUAL OPERATION
335
Manual feedrate overridesignals (*JV0 to *JV15) can be used to apply
an override (0.01% to 655.34%) to the feedrate.
Never use the mirror image function when performing manual operation.
(Perform manual operation when the mirror image switch (MI1 ℘ MI3)
is off, and mirror image setting is off.)
Manual linear/circular interpolation can not used with two--path control.
The following signals determine the way in which jog feed or manual
handle feed is executed.
Selection Jog feed Manual handle feed
Mode selection MD1, MD2, MD4 MD1, MD2, MD4
Selection of the axis to
move
+J1, --J1, +J2, --J2, +J3,
HS1A, HS1B, HS1C,
HS1D, HS2A, HS2B,
Selection of the direc-
tion to move the axis
--J3, ...
+J8, --J8, +Jg, --Jg, +Ja,
--Ja, ...
HS2C, HS2D, HS3A,
HS3B, HS3C, HS3D
Selection of the move
amount
MP1, MP2
Selection of feedrate *JV0 -- *JV15
For the signals selecting the mode, see Section 2.6, “Mode Selection
Signals.” For the manual handle feed selection signals, MP1 and MP2 of
selection of the move amount, see 3.2 “Manual handle feed.” For manual
feedrate override signals *JV0 -- *JV15, see Section 3.1, “Jog
feed/incremental feed.”
Other signals are described below.
Limitations
D Mirror image
D Two--path control
Signal