1.AXIS CONTROL B-63323EN-1/03
- 86 -
5428 Pitch error compensation value at the reference position when a movement
is made to the reference position in the direction opposite to the reference
position return direction
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] detection unit
[Valid data range] -32768 - 32767
By using an absolute value, set a pitch error compensation value at
the reference position when a movement is made to the reference
position in the negative direction if the reference position return
direction (bit 5 (ZMI) of parameter No. 1006) is positive, or when a
movement is made to the reference position in the positive direction
if the reference position return direction is negative.
Caution
CAUTION
1 To use this function, the stored pitch error
compensation option is required.
2 This function is enabled after a manual reference
position return or an automatic reference position
return with the same sequence as that of a manual
reference position return is performed. When an
absolute position detector is used, however, the
function is enabled after the power is turned on.
3 When the machine moves to the reference position in
the reference position return direction, set the
absolute value of the pitch error compensation pulse
to 0.
4 When this function and backlash compensation are
used at the same time, the pulse resulting from
backlash compensation is superimposed on the
compensation pulse when the travel direction is
reversed.
5 When this function is used for a rotation axis, the sum
of the pitch error compensation amounts per rotation
about the rotation axis must be 0 for both the positive
and negative directions.
6 When the interpolated pitch error compensation
function is used, interpolated pitch error
compensation is applied to both the positive and
negative direction.