1.AXIS CONTROL B-63323EN-1/03
- 208 -
First axis : X-axis
Second axis : Y-axis
Third axis : Z-axis
Fourth axis : U-axis
To synchronize the U-axis with X-axis, set the parameters as follows:
X: 0
Y: 0
Z: 0
U: 1
7723 Maximum error in synchronous error checking based on machine
coordinates
[Input type] Parameter input
[Data type] Realaxis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 0 or positive 9 digit of minimum unit of data (refer to the standard
parameter setting table (B))
(When the increment system is IS-B, 0.0 - +999999.999)
This parameter sets the maximum allowable difference between the
master axis and the slave axis machine coordinate value when the
synchronous error check based on machine coordinates is used. If the
difference of machine coordinates exceeds the value specified in this
parameter, an alarm (OT513) is issued.
Set this parameter to the slave axis.
7724 Maximum compensation value in synchronization alignment based on
machine coordinates
[Input type] Parameter input
[Data type] Realaxis
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] 0 or positive 9 digit of minimum unit of data (refer to the standard
parameter setting table (B))
(When the increment system is IS-B, 0.0 - +999999.999)
This parameter sets the maximum compensation value for
synchronization alignment. If a compensation value exceeds the value
specified with this parameter, an alarm (OT513) is issued, and the
compensation alignment is not performed.
Set this parameter to the slave axis.