6.INTERPOLATION FUNCTION B-63323EN-1/03
- 566 -
6.5 SINGLE DIRECTION POSITIONING
General
For accurate positioning without play of the machine (backlash), final
positioning from one direction is available.
Fig.6.5 (a) Direction positioning process
An overrun and a positioning direction are set by the parameter (No.
6820).
Even when a commanded positioning direction coincides with that set by
the parameter, the tool stops once before the end point.
G60, which is an one-shot G-code, can be used as a modal G-code in
group 01 by setting 1 to the parameter (No. 7616 bit 0 G60).
This setting can eliminate specifying a G60 command for every block.
Other specifications are the same as those for an one-shot G60 command.
When an one-shot G code is specified in the single direction positioning
mode, the one-shot G command is effective like G codes in group 01.
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
7616 G60
! >! 4 >!"&
!!" !)"#
!$ ?& !!"
)$ . !)"
Start position
End position
Temporary stop
Start position
Overrun