1.AXIS CONTROL B-63323EN-1/03
- 284 -
Signal
Power failure deceleration signal PWFL <G159#3>
[Classification] Input signal
[Function] Posts the detection of a power failure.
[Operation] When this signal is set to 1, the control unit operates an follows:
Immediately performs deceleration stop according to an acceleration
value set in parameter No. 1670.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G159 PWFL
Parameter
1670 Acceleration for each axis for deceleration stop at power failure
"
# , , $ , , $, , % &
2 34!
%&!
%A $.!.+.....!.!A $.!.
+....!.&
Set an acceleration value by which deceleration stop is to be performed for the
target axis at power failure.
If this parameter is set to 0 for an axis, deceleration is not performed for that axis
upon a power failure.
In synchronization control and tandem control, set the same parameter value for
both the master and slave axes.