B-63323EN-1/02 5.AUTOMATIC OPERATION
- 487 -
Signal
Manual absolute Signal
ABS<G004#5>
[Classification] Input signal
[Function] Turns off the manual absolute function.
[Operation] When this signal is set to 1, the control unit operates as follows:
Turns off the manual absolute function.
Manual absolute check Signal
MABSM<F004#5>
[Classification] Output signal
[Function] Notifies the PMC of the state of the manual absolute
signal.
[Output condition] This signal is set to 1 in the following case:
- When the manual absolute signal *ABS is set to 0
This signal is set to 0 in the following case:
- When manual absolute signal *ABSM is set to 1
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
G004 ABS
F004 MABS
Manual
Intervention
Program tool path
The tool moves along this path, regardress of absolute
command or incremental command