1.AXIS CONTROL B-63323EN-1/03
- 124 -
2 <D !
#+ #+
,# - $
%& '
&
/#+ &#%
+ E # $
1( !#+
#!(7($
! #+
<D7$
; <
%& # $
& # ,# -$
#7 #6 #5 #4 #3 #2 #1 #0
1816 ACM
[Input type] Parameter input
[Data type] Bitaxis
#1 to #3: DM1 to DM3 detection multiplier setting
Setting
DM3 DM2 DM1
Detection
multiplier
0
0
0
0
1
1
1
1
0
0
1
1
0
0
1
1
0
1
0
1
0
1
0
1
1/2
1
3/2
2
5/2
3
7/2
4
NOTE
1 To use flexible feed gears, set the respective DMR numerators
and denominators in parameter No. 1977 and No. 1978.
2 Set DM3 to DM1 to 111 for those axes to be subjected to
spindle positioning.