B-63323EN-1/03 3.MANUAL OPERATION
- 349 -
Feed Axis and Direction Selection Signal
+J1<G65#0>, +J2<G69#0>, ... , -J1<G65#1>, -J2<G69#1>, ...
[Classification] Input signal
[Function] Selects a desired feed axis and direction in jog feed or incremental feed.
The sign (+ or -) in the signal name indicates the feed direction. The
number following J indicates the number of the control axis.
x J y
x : + ..... Feed in positive direction
- ..... Feed in negative direction
y : 1 ..... First axis is fed
2 ..... Second axis is fed
3 ..... Third axis is fed
::
[Operation] When the signal is high, the control unit operates as described below.
- When jog feed or incremental feed is allowed, the control unit
moves the specified axis in the specified direction.
- In jog feed, the control unit continues to feed the axis while the
signal is "1".
- In incremental feed, the control unit feeds the specified axis by the
step distance which is specified by the manual handle feed move
distance selection signals DIST0 to DIST26. Then the control
unit stops it. Even if the signal is set to "0" while the axis is being
fed, the control unit does not stop feeding it.
To feed the axis again, set the signal to "0", then set it to "1" again.
NOTE
1 If both the positive direction and negative direction
signals of the same axis are simultaneously set to
"1", neither the positive direction nor the negative
direction is selected. The control unit assumes that
both these signals are set to "0".
2 If the feed axis and direction selection signals are
set to "1" before the jog feed mode or incremental
feed mode is selected, these signals are invalidated.
After the jog feed mode or incremental feed mode is
selected, set these signal to "0", then set them to "1"
again.
Jog mode
+J1
1st axis move
Incremental feed mode
+J1
1st axis move