
B-63323EN-1/02 14.PMC CONTROL FUNCTION
- 1373 -
#7 #6 #5 #4 #3 #2 #1 #0
2405 NPA
[Input type] Parameter input
[Data type] Bit
# 5 NPA When movement along the PMC control axis is specified by an NC
program:
0: The alarm PS0450 occurs.
1: The alarm PS0450 does not occur.
NOTE
If 1 is selected, the CNC move command is
ignored.
7767 Allowable cumulative movement value for torque control
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] detection unit
[Valid data range] 0 - 32767
Set an allowable cumulative movement value in the torque control
mode.
If the cumulative movement value exceeds the value set in this
parameter, a servo alarm (SV0126) is issued.
NOTE
This parameter is valid when bit 3 (TQF) of
parameter No. 1409 is set to 0.
7768 Torque control cancellation limit
[Input type] Parameter input
[Data type] Integeraxis
[Unit of data] detection unit
[Valid data range] 1 - 32767
Set a cancellation limit value used to cancel the torque control mode.
When the torque control mode is canceled, position control is
resumed if the positional deviation becomes equal to or less than the
setting of this parameter.
NOTE
This parameter is valid when bit 3 (TQF) of
parameter No. 1409 is set to 0.