B-63323EN-1/03 1.AXIS CONTROL
- 93 -
NOTE
Once this parameter is re-set, it is necessary to switch
the power off and on again.
# 6 RBK Specifies whether to perform cutting-/rapid traverse-specific backlash
compensation as follows:
0: Do not perform.
1: Perform.
#7 #6 #5 #4 #3 #2 #1 #0
5426 HPE
[Input type] Parameter input
[Unit of data] Bit axis
NOTE
Once this parameter is re-set, it is necessary to switch
the power off and on again.
# 3 HPE Specifies the actual detection unit for the output of interpolation-type
pitch error compensation, third-dimensional error compensation,
interpolation-type straightness compensation, and smooth backlash
compensation as follows:
0: Detection unit
1: 1/1000 of detection unit (the same unit as for nano interpolation)
NOTE
1.Even when this parameter is set to 1, the measurement
unit of already set compensation data remains to be
the detection unit. So, it is unnecessary to change the
compensation data.
2.Even when this function is enabled, the servo output
for the following functions remains to be in the
detection unit:
Stored pitch error compensation, gradient
compensation, straightness compensation, and 128-
point straightness compensation.
1846 Distance at which the second stage of smooth backlash compensation begins
[Input type] Parameter input
[Unit of data] Integer axis
[Valid data range] Detection unit
[Valid data range] 0 to 999999999
This parameter specifies the distance where the second stage of smooth
backlash compensation begins from a point where the direction of axis
movement is reversed for individual axes.