1.AXIS CONTROL B-63323EN-1/03
- 102 -
Thermal growth compensation data THD00 to THD15<G178,G179>
[Classification] Input signal
[Function n Compensation is applied to the corresponding axis,
and the tool moves.
An offset value in the range 0 to }9,999 is to be
specified in binary, using the detection unit.
This function is valid only for the same detection
of basic three axes.
The offset value is always an absolute value, so
the tool moves by the difference between a new
specified offset value and the previous value.
If a large compensation is applied at a time, an
excessive error will be occurred.
When the tool is stopped, then raising an alarm.
So, to apply a large compensation, the operation
must be divided into several input steps.
Signals address
#7 #6 #5 #4 #3 #2 #1 #0
G161 THML
F179 MTHML
G161 THSTB
F170 THREND
G178 THD07 THD06 THD05 THD04 THD03 THD02 THD01 THD00
G179 THD15 THD14 THD13 THD12 THD11 THD10 THD09 THD08
Parameter
6080 Rotation axis for three-dimensional cutter compensation and so forth (first
group)
6081 Linear axis 1 for three-dimensional cutter compensation and so forth (first
group)
6082 Linear axis 2 for three-dimensional cutter compensation and so forth (first
group)