12.DISPLAY/SET/EDIT B-63323EN-1/03
- 1180 -
Alarm class signal
OTALM<F6#3>
[Classification] Output signal
[Function] Used to inform the operator that an OT alarm has occurred.
[Output condition] The signal goes to 1 when:
- An OT alarm occurs.
The signal is held to 0 when:
- No OT alarm is present.
Alarm class signal
SYALM<F6#4>
[Classification] Output signal
[Function] Used to inform the operator that an SY alarm has occurred.
[Output condition] The signal goes to 1 when:
- An SY alarm occurs.
The signal is held to 0 when:
- No SY alarm is present.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
F000 AL
#7 #6 #5 #4 #3 #2 #1 #0
F006 SYALM OTALM OHALM SVALM PSALM
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
8000 PRA NAP
! 7-1 &''**
*'''*&
!
5 10- '*16*!
(+'*,
'*
! '*
Reference item
Series15i/150i-MA Operator’s Manual
(Operation)
(B-63324EN-1)
II-10.7 Alarm display