B-63323EN-1/02 14.PMC CONTROL FUNCTION
- 1349 -
NOTE
If specification by diameter is selected in parameter
DIA (bit 3 of parameter No. 1006), parameter NDI (bit
7 of parameter No. 1404) can be used to specify the
value (radius or diameter) that is to be used.
(4) Axis control data signal
DT1X31 - DT1X0<G391#7 - G388#0>, DT2X31 - DT2X0 <G399#7 - G396#0>, ...
[Classification] Input signal
[Function]
DTX31 - DT
X0
: 1 ..... Axis control data for the first axis
2 ..... Axis control data for the second axis
3 ..... Axis control data for the third axis
::
(1) Rapid traverse (CDxX7 to CDxX0: 00h)
(2) Cutting feed - feed per minute (CDxX7 to CDxX0: 01h)
(3) Cutting feed - sec/block specification
(CDxX7 to CDxX0: 02h)
(4) Cutting feed--feed per revolution (CDxX7 to CDxX0: 12h)
(5) Skip--feed per revolution (CDxX7 to CDxX0: 13h)
The incremental amount of travel in the input unit for an axis is
specified with binary code.
[Unit of data] Least input increment of each axis
[Valid data range]
IS-A IS-B - IS-E
Valid data range
-99999999 - 99999999 -999999999 - 999999999
(6) Machine coordinate system selection
(CDxX7 to CDxX0: 06h)
The amount of travel along an axis is specified with an absolute
position indicated by machine coordinates in the input unit.
[Unit of data] Least input increment for each axis
[Valid data range]
IS-A IS-B - IS-E
Valid data range
-99999999 - 99999999 -999999999 - 999999999
(7) Dwell (CDxX7 to CDxX0: 07h)
The dwell time is specified using binary code.
[Unit of data] msec
[Valid data range] 0 - 999999999
(8) Auxiliary function (CDxX7 to CDxX0: 08h)
The selection number of an auxiliary function signal used is
specified using two-digit binary code.
The auxiliary function code sent to the PMC is specified using
two-digit binary code.
DTxX15 to DTxX08 = selection number
DTxX07 to DTxX00 = auxiliary function code