3.MANUAL OPERATION B-63323EN-1/03
- 360 -
Parameter
1413 Maximum number of buffered manual handle feed pulses
[Input type] Parameter input
[Data type] Integer
[Valid data range] 0 - 4
The permissible flow amount is set. If such a handle feed that
momentarily exceeds the rapid traverse rate is specified, the handle
pulses for the excess of the rapid traverse rate are not discarded,
but are accumulated according to the setting.
?5##
)setting(
)rate traverserapid(
amount flow ePermissibl
×
=
Normally, 0 may be set.
1414 Magnification m of manual handle feed
!
.! #0###
Set the magnification m for when movement selection signals MP1 and MP2 for
manual handle feed are 0 and 1, respectively.
Travel amount select signal
MP4 MP2 MP1
Amount of travel
(manual handle feed)
0 0 0 Least input increment×1
0 0 1 Least input increment×
0 1 0 Least input increment×m
-1
011
Least input increment×n
-2
*1 To be set in parameter No.1414.
*2 To be set in parameter No.1418.