B-63323EN-1/03 5.AUTOMATIC OPERATION
- 545 -
#7 #6 #5 #4 #3 #2 #1 #0
7616 EXT
NOTE
After setting this parameter, turn the power off then back on.
6 : &%3.#
@ &%3.#
!@ &%3.#
03%&%3.
.%(+!->%+%#
Notes
- External device subprogram call
To perform external device subprogram calls, set a value to specify a
program number for the address P format. SFL (bit 5 of parameter No.
2404) = 0
The following tables list the specified P values and corresponding
called file names.
P1 to P9999 : "O" + 4-digit number (without zero suppression)
Examples)
Program command Called file name
P1 O0001
P12 O0012
P123 O0123
P1234 O1234
P10000 to P9999999: "O" + 7-digit number (without zero suppression)
Examples)
Program command Called file name
P10000 O0010000
P1234567 O1234567
P10000000 to P99999999: 8-digit number (without zero suppression)
Examples)
Program command Called file name
P10000000 10000000