1.AXIS CONTROL B-63323EN-1/03
- 66 -
#7 #6 #5 #4 #3 #2 #1 #0
5580 SMT
[Input type] Parameter input
[Data type] Bit
# 1 SMT The parameters (No. 5591 to No. 5595) for straightness
compensation multiplier:
0: Are effective only for the first move axis when two or more move
axes are set using the same axis number.
1: Are effective for the respective move axes even when two or more
move axes set using the same axis number.
When the straightness compensation function is used, be sure to set
SCMT to 1.
Alarm and message
Number Message Contents
PW0100 ILLEGAL PARAMETER (S-COMP.)
The parameter for setting slope compensation is incorrect.
This alarm occurs in the following cases:
• When the number of pitch error compensation points on
the axis on which slope compensation is executed
exceeds 128 between the most negative side and most
positive side
• When the size relationship between the slope
compensation point Nos. is incorrect
• When the slope compensation point is not located
between the most negative side and most positive side of
pitch error compensation
• When the compensation per compensation point is too
small or too great.
SV0100 S-COMP. VALUE OVERFLOW
The value set for straightness compensation has exceeded
maximum value 32,767.